EXIN CDCS Exam Questions - Updated Frequently

Wiki Article

What's more, part of that Prep4SureReview CDCS dumps now are free: https://drive.google.com/open?id=1CEkaaVhSzoSx1ZPE_ruPzQkAZHRqkcwB

The EXIN CDCS web-based practice exam software can be easily accessed through browsers like Safari, Google Chrome, and Firefox. The customers do not need to download or install excessive software or applications to take the EXIN EPI Certified Data Centre Specialist (CDCS) web-based practice exam. The CDCS web-based practice exam software format can be accessed through any operating system like Windows or Mac.

If you want to know more about our test preparations materials, you should explore the related CDCS exam Page. You may go over our CDCS brain dumps product formats and choose the one that suits you best. You can also avail of the free demo so that you will have an idea how convenient and effective our CDCS exam dumps are for CDCS certification. With Prep4SureReview, you will not only get a single set of PDF dumps for CDCS Exams but also a simulate software for real exams. Rather we offer a wide selection of braindumps for all other exams under the CDCS certification. This ensures that you will cover more topics thus increasing your chances of success. With the multiple learning modes in CDCS practice exam software, you will surely find your pace and find your way to success.

>> Study CDCS Test <<

Get CDCS Exam Questions To Achieve A High Score

There are rare products which can rival with our products and enjoy the high recognition and trust by the clients like our products. Our products provide the CDCS test guide to clients and help they pass the test CDCS certification which is highly authorized and valuable. Our company is a famous company which bears the world-wide influences and our CDCS Test Prep is recognized as the most representative and advanced study materials among the same kinds of products. Whether the qualities and functions or the service of our product, are leading and we boost the most professional expert team domestically.

EXIN CDCS Exam Syllabus Topics:

TopicDetails
Topic 1
  • Data Centre Environmental Considerations and Efficiency: This section evaluates the proficiency of data center professionals in addressing environmental factors and promoting efficiency within data center operations. The target audience, including data center managers and engineers, will be tested on their ability to identify and implement measures that enhance energy efficiency, cooling management, and sustainable practices.
Topic 2
  • Designing and Implementing a Data Centre: In this module, the exam assesses the knowledge of Exin data center professionals tasked with the design and implementation of data centers. Candidates will learn the key principles of creating an efficient data center layout, including considerations for scalability, redundancy, and security.
Topic 3
  • Data Centre Life Cycle and Standards: This section of the exam measures the skills of data center professionals and covers the various stages involved in the life cycle of a data center, from planning and design to implementation and decommissioning.

EXIN EPI Certified Data Centre Specialist Sample Questions (Q74-Q79):

NEW QUESTION # 74
What is the effect of having a damper (in open position) construction in a raised-floor tile?

Answer: B

Explanation:
Perforated tiles with integrated dampers are common in raised-floor data centers because they allow airflow regulation at the rack level. However, even when the damper is fully open, the mechanism inside the tile restricts airflow. This typically reduces the delivered airflow by around 10% compared to a non-dampered tile of the same type.
* Option A is incorrect because dampers do not affect supply temperature; they only throttle volume.
* Option B is wrong since dampers cannot increase volume-they only add resistance.
* Option D is partially true that dampers help with temperature balancing, but the main effect (in open position) is volume reduction.
Thus, the technical impact of dampers in open position is a slight airflow reduction, usually quantified as
~10%.
References: ASHRAE TC 9.9 - "Airflow Management in Raised-Floor Environments," ANSI/TIA-942-B §6.
5 (Cooling Infrastructure).


NEW QUESTION # 75
What is the calculation for the desired attenuation factor for shielding material?

Answer: B

Explanation:
The attenuation factor for shielding material is typically calculated using the formula A = 20 log (R / M). This equation provides the attenuation in decibels (dB), where R represents the measured electromagnetic field strength, and M is the maximum acceptable level. The logarithmic scale helps quantify how much the shielding reduces EMF levels relative to the maximum allowable value.
Detailed Explanation:
This formula calculates attenuation by comparing the measured value with the acceptable threshold, with the result expressed in decibels. A higher attenuation indicates more effective shielding material, essential for environments requiring robust EMF management.
EPI Data Center Specialist References:
EPI standards include the use of logarithmic formulas to evaluate attenuation levels, ensuring that shielding materials provide adequate reduction in EMF to protect sensitive equipment within data centers.


NEW QUESTION # 76
You are installing new copper cabling.
What is the advantage or disadvantage of choosing pre-terminated category 6 or 6A cabling?

Answer: B

Explanation:
Choosing pre-terminated category 6 or 6A cabling provides several advantages, primarily related to time savings and reliability. Since pre-terminated cables are factory tested, they ensure consistent quality and performance, reducing the need for additional testing during installation. This makes installation faster and more efficient, which can significantly reduce labor costs and deployment times.
Detailed Explanation:
Pre-terminated cabling systems are manufactured and tested in controlled environments, which ensures they meet industry standards for performance. This factory testing process minimizes the likelihood of faults, reducing the need for troubleshooting and retesting on-site. Moreover, pre-terminated solutions can help to streamline installations because they eliminate the need for on-site terminations, which can be time-consuming and require skilled labor.
This is especially beneficial for data centers, where rapid deployment and minimizing potential points of failure are critical to maintaining uptime. However, it is important to note that pre-terminated cables require accurate planning, as lengths and connector configurations must be predetermined.
EPI Data Center Specialist References:
According to EPI Data Center Specialist guidelines, pre-terminated cabling is advantageous in data center environments due to reduced installation time and enhanced reliability from factory testing. These attributes align with best practices for efficient data center management, where maintaining performance and minimizing downtime are priorities.


NEW QUESTION # 77
A 5kW (power consumption) server keeps crashing with the message 'temperature too high'.
The intake temperature is measured at 25 °C/77 °F and a relative humidity (RH) level of 50%.
The exhaust temperature is 29 °C/84 °F and 45% RH.
The raised floor is providing an adequate amount of CFM/CMH at a reasonable velocity.
The pressure under the raised floor is approximately 25 Pa/0.1 inch H#O.
Analyze the situation and indicate what the most likely cause is for this server to crash.

Answer: D

Explanation:
The server's repeated overheating despite adequate intake and exhaust temperatures suggests that dust buildup inside the server may be impeding heat transfer. Dust accumulation can obstruct airflow within the server, insulate components, and disrupt the convection-based cooling systems that regulate internal temperatures, leading to overheating and potential hardware failures.
Detailed Explanation:
While the intake and exhaust temperatures appear within acceptable ranges, internal dust can reduce airflow and impede cooling efficiency, causing internal components to overheat despite seemingly normal ambient conditions. Regular cleaning and maintenance are critical for preventing dust-related issues, especially in high- powered equipment like a 5kW server.
EPI Data Center Specialist References:
EPI emphasizes regular maintenance to prevent dust buildup in data center equipment. Dust can significantly impact cooling efficiency and lead to overheating, which underlines the importance of routine cleaning for optimal server performance.


NEW QUESTION # 78
You are allowed to use a calculator for this question. The total power consumption of the ICT equipment in a rack is 6 kW. The equipment is traditional ICT equipment with a Delta-T of approximately 11 °C / 20 °F.
Calculate the approximate CFM required to cool the equipment in the rack.

Answer: D

Explanation:
To calculate the cooling airflow requirement for ICT equipment, you can use the formula:
CFM=Power (kW)×3160#T(°F) ext{CFM} = rac{ ext{Power (kW)} imes 3160}{Delta T ( ext{°F})} CFM=#T(°F)Power (kW)×3160 For equipment consuming 6 kW with a Delta-T of 20°F:
CFM=6×316020=948#1,000 CFM ext{CFM} = rac{6 imes 3160}{20} = 948 approx 1,000 , ext{CFM} CFM=206×3160=948#1,000CFM Detailed Explanation:
This formula provides an estimate of the cubic feet per minute (CFM) of air required to cool the equipment based on its power consumption and the temperature difference (Delta-T) between intake and exhaust. The Delta-T represents the cooling effectiveness of the airflow.
EPI Data Center Specialist References:
EPI recommends using this calculation for determining airflow requirements in data centers, ensuring that cooling systems are adequately sized to maintain equipment within safe temperature limits.


NEW QUESTION # 79
......

The second format Prep4SureReview also has a product support team available every time to help you out in any terms. And they will fix all of your problems on time. provides its users to study for Prepare for your EXIN EPI Certified Data Centre Specialist (CDCS) exam is web-based practice exam. This format has all the features of desktop practice exam software for EXIN CDCS exam preparation.

CDCS Valid Exam Tutorial: https://www.prep4surereview.com/CDCS-latest-braindumps.html

P.S. Free & New CDCS dumps are available on Google Drive shared by Prep4SureReview: https://drive.google.com/open?id=1CEkaaVhSzoSx1ZPE_ruPzQkAZHRqkcwB

Report this wiki page